1.1 | Date updated: | Jan 22, 2020 |
1.2 | Vessel's name (IMO number): | Gas Al Ahmadiah (9849629) |
1.3 | Vessel's previous name(s) and date(s) of change: | Not Applicable |
1.4 | Date delivered / Builder (where built): | Jan 08, 2020 / Hyundai Heavy Industries - Ulsan |
1.5 | Flag / Port of Registry: | Kuwait / KUWAIT |
1.6 | Call sign / MMSI: | 9KJW / 447727500 |
1.7 | Vessel's contact details (satcom/fax/email etc.): | Tel: +870 773942195 Fax: +870 783323317 Email: gah@kotc.com.kw |
1.8 | Type of vessel (as described in Form A or Form B Q1.11 of the IOPPC): | Other |
1.9 | Type of hull: | Double Hull |
1.10 | Registered owner - Full style: | Kuwait Oil Tanker Company S.A.K. Shuwaikh Administrative Area, Jamal Abdul Nasser Street, Block No.4 Kuwait. PO Box 810 Safat 13009, Kuwait Kuwait Tel: +965 24625028 / 29 Fax: +965 24913597 / +965 Email: ho-email@kotc.com.kw |
1.11 | Technical operator - Full style: |
Company IMO#: 0100261 |
1.12 | Commercial operator - Full style: | KUWAIT PETROLEUM CORPORATION Oil Sector Complex - 10th floor Arabian Gulf Street - Shuwaikh P.O. BOX 26565,Safat Pin Code 13126 KUWAIT Kuwait Tel: +965 24912790 / 1 Fax: +965 24912792/3/4/5 Email: marineops@kpc.com.kw |
1.13 | Disponent owner - Full style: | |
1.14 | P & I Club - Full Style: | Swedish Club |
1.15 | P & I Club pollution liability coverage / expiration date: | US$ | |
1.16 | Hull & Machinery insured by - Full Style: (Specify broker or leading underwriter) | |
1.17 | Hull & Machinery insured value / expiration date: | US$ | |
1.18 | Classification society: | Nippon Kaiji Kyokai |
1.19 | Class notation: | NS* / MNS*(LGC 2G, PSPC-WBT, NC)(PS-DA&FA/40)(IWS)(PSCM)(IHM)(NOx-III(SCR))(MO) |
1.20 | Is the vessel subject to any conditions of class, class extensions, outstanding memorandums or class recommendations? If yes, give details: |
|
1.21 | If classification society changed, name of previous and date of change: | , Not Applicable |
1.22 | Does the vessel have ice class? If yes, state what level: | , |
1.23 | Date / place of last dry-dock: | / |
1.24 | Date next dry dock due / next annual survey due: | Jan 07, 2025 | |
1.25 | Date of last special survey / next special survey due: | | Jan 07, 2025 |
1.26 | If ship has Condition Assessment Program (CAP), what is the latest overall rating: | , |
1.27 | Length overall (LOA): | 228.45 m |
1.28 | Length between perpendiculars (LBP): | 222.60 m |
1.29 | Extreme breadth (Beam): | 36.60 m |
1.30 | Moulded depth: | 22.55 m |
1.31 | Keel to masthead (KTM)/ Keel to masthead (KTM) in collapsed condition, if applicable: | 54.43 m | m |
1.32 | Distance bridge front to center of manifold: | 73.10 m |
1.33 | Bow to center manifold (BCM) / Stern to center manifold (SCM): | 116.09 m | 112.30 m |
1.34 | Parallel body distances: | Lightship | Normal Ballast | Summer Dwt |
Forward to mid-point manifold: | 33.60 m | 42 m | 42 m |
Aft to mid-point manifold: | 22.22 m | 43.57 m | 61.62 m |
Parallel body length: | m | m | m |
1.35 | Net Tonnage: | 18,997 |
1.36 | Gross Tonnage / Reduced Gross Tonnage (if applicable): | 49,394 | |
1.37 | Suez Canal Tonnage - Gross (SCGT) / Net (SCNT): | 53,121.93 | 51,922.14 |
1.38 | Panama Canal Net Tonnage (PCNT): | 40,715 |
1.39 | Loadline | Freeboard | Draft | Deadweight | Displacement |
Summer: | 6.44 m | 11.919 m | 54,503 MT | 74,050 MT |
Winter: | 6.69 m | 11.671 m | 52,749 MT | 72,296 MT |
Tropical: | 6.19 m | 12.167 m | 56,262 MT | 75,809 MT |
Lightship: | 14.77 m | 3.59 m | | 19,547 MT |
Normal Ballast Condition: | 11.64 m | 6.72 m | 19,511 MT | 39,058 MT |
1.40 | FWA/TPC at summer draft: | 261 mm | 70.84 MT |
1.41 | Does vessel have multiple SDWT? If yes, please provide all assigned loadlines: | No
|
1.42 | Constant (excluding fresh water): | MT |
1.43 | What is the company guidelines for Under Keel Clearance (UKC) for this vessel? | |
1.44 | What is the max height of mast above waterline (air draft) | Full Mast | Collapsed Mast |
Summer deadweight: | 42.511 m | 0 m |
Normal ballast: | 46.79 m | 0 m |
Lightship: | 50.84 m | 0 m |
|
2.1 | Safety Equipment Certificate (SEC): | Jan 08, 2020 | Jan 08, 2020 | | Jun 07, 2020 |
2.2 | Safety Radio Certificate (SRC) | Jan 08, 2020 | Jan 08, 2020 | | Jun 07, 2020 |
2.3 | Safety Construction Certificate (SCC): | Jan 08, 2020 | Jan 08, 2020 | | Jun 07, 2020 |
2.4 | International Loadline Certificate (ILC): | Jan 08, 2020 | Jan 08, 2020 | | Jun 07, 2020 |
2.5 | International Oil Pollution Prevention Certificate (IOPPC): | Jan 08, 2020 | Jan 08, 2020 | | Dec 07, 2019 |
2.6 | International Ship Security Certificate (ISSC): | Jan 08, 2020 | Jan 08, 2020 | Not Applicable | Jun 07, 2020 |
2.7 | Maritime Labour Certificate (MLC): | | | | |
2.8 | ISM Safety Management Certificate (SMC): | Jan 08, 2020 | Jan 08, 2020 | Not Applicable | Jun 07, 2020 |
2.9 | Document of Compliance (DOC): | Dec 15, 2019 | Dec 15, 2019 | | Jan 21, 2025 |
2.10 | USCG Certificate of Compliance (USCGCOC): | | Not Applicable | Not Applicable | |
2.11 | Civil Liability Convention (CLC) 1992 Certificate: | Nov 18, 2019 | | | |
2.12 | Civil Liability for Bunker Oil Pollution Damage Convention (CLBC) Certificate: | | | | |
2.13 | Liability for the Removal of Wrecks Certificate (WRC): | | | | |
2.14 | U.S. Certificate of Financial Responsibility (COFR): | Not Applicable | | | |
2.15 | Certificate of Class (COC): | | Jan 08, 2020 | | |
2.16 | International Sewage Pollution Prevention Certificate (ISPPC): | | | | |
2.17 | Certificate of Fitness (COF): | Jul 07, 2020 | | | |
2.17.1 | Noxious Liquids Substance Certificate (NLS): | Not Applicable | | | |
2.18 | International Energy Efficiency Certificate (IEEC): | | | | |
2.19 | International Air Pollution Prevention Certificate (IAPPC): | | | |
|
2.20 | Owner warrant that vessel is member of ITOPF and will remain so for the entire duration of this voyage/contract: | |
2.21 | Does vessel have in place a Drug and Alcohol Policy complying with OCIMF guidelines for Control of Drugs and Alcohol Onboard Ship? | Yes |
2.22 | Is the ITF Special Agreement on board (if applicable)? | |
2.23 | ITF Blue Card expiry date (if applicable): | |
|
3.1 | Nationality of Master: | Indian |
3.2 | Number and nationality of Officers: | 13 | Egyptian, Indian, Kuwaiti, Pakistani, Syrian, Croatian |
3.3 | Number and nationality of Crew: | 16 | Filipino |
3.4 | What is the common working language onboard: | |
3.5 | Do officers speak and understand English: | |
3.6 | If Officers/Crew employed by a Manning Agency - Full style: | Officers: Liberty Manning Services Ltd. P.O. Box 556, Main Street, Charlestown, Nevis. Operated from Kuwait Oil Tanker Company S.A.K. Shuwaikh Administrative Area, Jamal Abdul Nasser Street, Block No.4 Kuwait. PO Box 810 Safat 13009, Kuwait Tel: +965 24625028/9 Fax: +965 2491 3597/ 2462 Email: ho-email@kotc.com.kw
Crew:
|
|
4.1 | Has the vessel Operator submitted a Vessel Spill Response Plan to the US Coast Guard which has been approved by official USCG letter? | N/A |
4.2 | Qualified individual (QI) - Full style: | |
4.3 | Oil Spill Response Organization (OSRO) - Full style: | |
4.4 | Salvage and Marine Firefighting Services (SMFF) - Full Style: | |
|
5.1 | Is the vessel operated under a Quality Management System? If Yes, what type of system? (ISO9001 or IMO Resolution A.741(18) as amended): | Yes ISO9002 / IMO Res A 741(18) |
5.2 | Can the ship comply with the ICS Helicopter Guidelines? | No |
5.2.1 | If Yes, state whether winching or landing area provided: | |
5.2.2 | If Yes, what is the diameter of the circle provided: | m |
|
6.1 | Tank Coating | Coated | Type | To What Extent | Anodes |
Cargo tanks: | Yes | Inorganic Zinc Silicate | FULL | No |
Ballast tanks: | Yes | Polyamine cured pure Epoxy | FULL | Yes |
|
7.1 | Pumps: | No. | Type | Capacity | At What Head (sg=1.0) |
Ballast Pumps: | 2 | FEWV-300-2D, Vertical Centrifugal | 800 m3/hr | 40 m |
Ballast Eductors: | 2 | KDH-15 | 90 m3/hr | m |
|
8.1 | Does the vessel comply with GC/IGC Code requirements? | |
8.2 | What is the minimum/maximum permissible tank pressure? | -5 KP/CM2 | 450 KP/CM2 |
8.3 | What is the minimum permissible tank temperature? | -50 °C |
8.4 | Number of cargo tanks and total cubic capacity (98%): | | 0 m3 |
8.5 | Capacity (98%) of each natural segregation with double valve (specify tanks): | |
8.6 | Deck tank(s) capacity (98%): | Ammonia: m3 Butane: 251.60 m3 Propane: 251.60 m3 |
8.7 | What is vessel Ship Type? What type and of what material are the cargo tanks constructed? | , Type A,Carbon Manganese low temperature steel |
8.8 | Maximum allowable relief valve setting: | 0.45 Bar Gauge |
8.9 | What is total SBT capacity and percentage of SDWT vessel can maintain? | m3 | % |
8.10 | Number and capacity of compressors: | 3 | 443 m3/hr |
8.11 | Manufacturer/type of compressors: | BURCKHARDT 3K 160/Reciprocating |
8.12 | Max % Ethane the re-liquefaction plant can handle: | % |
8.13 | What is the maximum number of grades that can be loaded/carried/discharged simultaneously with complete segregation and without risk of contamination? | 2 |
8.14 | Are there any cargo tank filling restrictions? If yes, specify number of slack tanks, max s.g., ullage restrictions etc.: | , |
8.15 | Max loading rate for homogenous cargo (without vapour return): | m3/hr |
8.16 | Max loading rate for homogenous cargo per manifold (without vapour return): | m3/hr |
8.17 | Is ship fitted with a Cargo Control Room (CCR)? | |
8.18 | Can tank innage/ullage/pressure/temperature/reliquefaction plant status be read from the CCR? | Innage/Ullage:
Pressure:
Temperature:
Plant Status: |
8.19 | Gauges | Manufacturer | Type | Rated Accuracy |
Level gauges | Kongsberg | Other | 0.01 % |
Temperature gauges | Kongsberg | Resistance Thermometer MN 3927WU | 0.01 % |
Pressure gauges | Yokogawa | Pressure Transmitter, EJA530E | 0.05 % |
8.20 | Sampling connection type and size: | Screw | 12.50 mm |
8.21 | Do manifold arrangements comply with SIGTTO standards? | |
8.22 | What type of valves are fitted at manifold: | Butterfly |
8.23 | Manifold distance from center of manifold: Manifold Diagram | Dimension A: mm Dimension B: mm Dimension C: 3,375 mm Dimension D: 1,125 mm Dimension E: 1,125 mm Dimension F: 3,375 mm Dimension G: 5,625 mm Dimension H: mm |
8.24 | Distance manifold to ships side: | 4,250 mm |
8.25 | Distance manifold height above uppermost continuous deck: | 1,750 mm |
8.26 | Manifold height above light/load waterline: | 20,870 mm | 12,531 mm |
8.27 | Distance from rail of compressor room/platform to presentation flanges: | mm |
8.28 | Distance from deck of compressor room/platform to center of manifold: | mm |
8.29 | Reducers: | No. | Flange Rating | Size | Length |
ANSI Class 300: | 10 | 25 bar | mm | 650 mm |
ANSI Class 300 to 150: | 10 | 18 bar | mm | 590 mm |
ANSI Class 150: | 8 | 18 bar | mm | 500 mm |
8.30 | Reducers additional comments: | |
8.31 | Pipe flanges: (specify flange letter, duty, rating, size and face) |
Pipe Flange letter | Duty | Rating (bar) | Size | Raised/Flat face |
---|
ANSI 150 | VAPOUR | 18 | 254 | RAISED | ANSI 300 | CARGO | 25 | 256 | RAISED |
|
8.32 | Are local pressure gauges fitted outboard of the manifold valves? | Yes |
8.33 | Type of system: | Oil Fired |
8.34 | Capacity: | 5,300 m3/hr |
8.35 | Type of fuel used: | MDO |
8.36 | Composition of IG: | Percent |
Oxygen: | 0.50 % |
CO2: | 14 % |
IG-NOx: | 0 % |
IG-N2: | 85 % |
8.37 | N2 purity percentage/capacity generated by N2 generator: | Capacity |
95%: | m3/hr |
98%: | m3/hr |
99.5%: | m3/hr |
8.38 | Lowest dew point achievable: | -40 °C |
8.39 | Nitrogen liquid storage capacity: | m3 |
8.40 | How many cargo pumps can be run simultaneously at full capacity: | |
8.41 | Pumps | No./Tank | Type | Rate Per Pump | At What Head (sg=1.0) |
Cargo pumps: | 2 | | 600 m3/hr | 120 m liq col |
Booster pumps: | | | 15.17 m3/hr | 115 m liq col |
8.42 | Cargo re-heaters/vaporizers: | LPG Heater/ Vaporizer | Vaporizer |
Type: | Tube | Seawater |
Heating medium: | Seawater | |
|
9.1 | Wires (on drums) | No. | Diameter | Material | Length | Breaking Strength |
Forecastle: | | mm | | m | MT |
Main deck fwd: | | mm | | m | MT |
Main deck aft: | | mm | | m | MT |
Poop deck: | | mm | | m | MT |
9.2 | Wire tails | No. | Diameter | Material | Length | Breaking Strength |
Forecastle: | | mm | | m | MT |
Main deck fwd: | | mm | | m | MT |
Main deck aft: | | mm | | m | MT |
Poop deck: | | mm | | m | MT |
9.3 | Ropes (on drums) | No. | Diameter | Material | Length | Breaking Strength |
Forecastle: | 4 | 33 mm | HMPE | 220 m | 84 MT |
Main deck fwd: | 4 | 33 mm | HMPE | 220 m | 84 MT |
Main deck aft: | 2 | 33 mm | HMPE | 220 m | 84 MT |
Poop deck: | 6 | 33 mm | HMPE | 220 m | 84 MT |
9.4 | Other lines | No. | Diameter | Material | Length | Breaking Strength |
Forecastle: | | mm | | m | MT |
Main deck fwd: | | mm | | m | MT |
Main deck aft: | | mm | | m | MT |
Poop deck: | | mm | | m | MT |
9.5 | Winches | No. | No. Drums | Motive Power | Brake Capacity | Type of Brake |
Forecastle: | 2 | DBL | Hydraulic | 42 MT | BAND TYPE |
Main deck fwd: | 2 | DBL | Hydraulic | 42 MT | BAND TYPE |
Main deck aft: | 1 | DBL | Hydraulic | 42 MT | BAND TYPE |
Poop deck: | 3 | DBL | Hydraulic | 42 MT | BAND TYPE |
9.6 | Bitts, closed chocks/fairleads | No. Bitts | SWL Bitts | No. Closed Chocks | SWL Closed Chocks |
Forecastle: | 4 | MT | | MT |
Main deck fwd: | 6 | MT | | MT |
Main deck aft: | 4 | MT | | MT |
Poop deck: | 6 | MT | | MT |
9.7 | Number of shackles on port / starboard cable: | 12 / 13 |
9.8 | Type / SWL of Emergency Towing system forward: | KETA-45F | 2,000 MT |
9.9 | Type / SWL of Emergency Towing system aft: | KETSP-40A | 2,000 MT |
9.10.1 | What is size of closed chock and/or fairleads of enclosed type on stern: | 600 X 450 |
9.10.2 | What is SWL of closed chock and/or fairleads of enclosed type on stern: | 204 MT |
9.11 | What is SWL of bollard on poop deck suitable for escort tug: | 204 MT |
9.12 | Derrick / Crane description (Number, SWL and location): | Cranes: 1 x 10 Tonnes
|
9.13 | Accommodation ladder direction: | |
| Does vessel have a portable gangway? If yes, state length: | | m |
9.14 | Does the vessel meet the recommendations in the latest edition of OCIMF 'Recommendations for Equipment Employed in the Bow Mooring of Conventional Tankers at Single Point Moorings (SPM)'? | Yes |
9.15 | If fitted, how many chain stoppers: | 1 |
9.16 | State type / SWL of chain stopper(s): | TONGUE TYPE | 200 MT |
9.17 | What is the maximum size chain diameter the bow stopper(s) can handle: | 80 mm |
9.18 | Distance between the bow fairlead and chain stopper/bracket: | 3.70 m |
9.19 | Is bow chock and/or fairlead of enclosed type of OCIMF recommended size (600mm x 450mm)? If not, give details of size: | Yes
|
|
10.1 | Speed | Maximum | Economical |
Ballast speed: | Kts (WSNP) | Kts (WSNP) |
Laden speed: | Kts (WSNP) | Kts (WSNP) |
10.2 | What type of fuel is used for main propulsion / generating plant: | LSFO & MGO | LSFO , MGO |
10.3 | Type / Capacity of bunker tanks: | Fuel Oil: m3 Diesel Oil: m3 Gas Oil: m3 |
10.4 | Is vessel fitted with fixed or controllable pitch propeller(s): | Fixed |
10.5 | Engines | No | Capacity | Make/Type |
Main engine: | | Kw | |
Aux engine: | 3 | Kw | |
Power packs: | | m3 | |
Boilers: | 1 | 3 MT/Hr | |
10.6 | What is brake horse power of bow thruster (if fitted): | No, bhp |
10.7 | What is brake horse power of stern thruster (if fitted): | No, bhp |
10.8 | Main engine IMO NOx emission standard: | |
10.9 | Energy Efficiency Design Index (EEDI) rating number: | 5.89 |
|
11.1 | Does vessel comply with recommendations contained in OCIMF/ICS Ship To Ship Transfer Guide (Petroleum, Chemicals or Liquified Gas, as applicable)? | Yes |
11.2 | What is maximum outreach of cranes / derricks outboard of the ship's side: | 6.70 m |
11.3 | Date/place of last STS operation: | |
|
12.1 | Last three cargoes / charterers / voyages (Last / 2nd Last / 3rd Last): | |
12.2 | Has vessel been involved in a pollution, grounding, serious casualty or collision incident during the past 12 months? If yes, full description: | Pollution: No,
Grounding: No,
Casualty: ,
Repair: No,
Collision: No, |
12.3 | Date and place of last Port State Control inspection: | / |
12.4 | Any outstanding deficiencies as reported by any Port State Control? If yes, provide details: |
|
12.5 | Recent Oil company inspections/screenings (To the best of owners knowledge and without guarantee of acceptance for future business)*:
*"Approvals" are not given by Oil Majors and ships are accepted for the voyage on a case by case basis. | |
12.6 | Date / place of last SIRE inspection: | / |
12.6.1 | Date / place of last CDI inspection: | / |
12.7 | Additional information relating to features of the ship or operational characteristics: | None |